Ptfe Coating Endoscopic Hydrophilic Zebra Guide Wire with Tip

Ptfe Coating Endoscopic Hydrophilic Zebra Guide Wire with Tip

Short Description:

Product Detail:

Super Nitinol Core Wire: Visual tip under fluoroscopy.

Radiopaque marker: allows maximum deflection without kinks.

Hydrophilic Coating – Reduces friction to facilitate advancement.

Different tip options: to meet different needs, choice of smoothness or stiffness, Angled or straight tips.


Product Detail

Product Tags

Application

Designed for use in the endoscopic treatment of the biliary and pancreatic ducts, assisting in the introduction of other devices in the tract

Specification

Model No. Tip Type Max. O.D. Working Length ± 50 (mm)
± 0.004 (inch) ± 0.1 mm
ZRH-XBM-W-2526 Angle 0.025 0.63 2600
ZRH-XBM-W-2545 Angle 0.025 0.63 4500
ZRH-XBM-Z-2526 Straight 0.025 0.63 2600
ZRH-XBM-W-2545 Straight 0.025 0.63 4500
ZRH-XBM-W-3526 Angle 0.035 0.89 2600
ZRH-XBM-W-3545 Angle 0.035 0.89 4500
ZRH-XBM-Z-3526 Straight 0.035 0.89 2600
ZRH-XBM-Z-3545 Straight 0.035 0.89 4500
ZRH-XBM-W-2526 Angle 0.025 0.63 2600
ZRH-XBM-W-2545 Angle 0.025 0.63 4500

Products Description

certificate
certificate
p14
p1

Anti-twist inner Niti core wire
Offering an excellent twisting and pushing force.

Smooth Smooth PTFE zebra coating
Easier to pass through the working channel, without any stimulation for tissue.

p2
p3

Yellow & Black Coating
Easier to track the guide wire and obvious under X-Ray

Straight tip design and angled tip design
Providing more control options for doctors.

p4
p5

Customized services
Such as the blue and white coating.

Use the ERCP guidewire to exchange various instruments, making the operation more accurate and safer

Using ERCP guidewire flexibly can reduce operation time. If during radiography, smart knife with ERCP guidewire is directly used, decision of cutting can be made after radiography.

If cutting is needed, insert ERCP guidewire into bile duct, incision knife will not easily roll out of ERCP bile duct stent, and operation time is saved. If therapy shall be conducted after cutting, insert ERCP guidewire again into bile duct or pancreatic duct and withdraw incision knife, and replace with corresponding equipment.

During operation process, remember that don't pull away ERCP guidewire. Sometimes ERCP guidewire cannot enter original pipeline after abjection. When tumor at hepatic portal vein needs double bracket or multiple brackets, use double ERCP guidewires. Using ERCP guidewire flexibly can improve working efficiency obviously.