A biopsy is the removal of tissue from any part of the body to examine it for disease.
The disposable biopsy forceps works with flexible endoscopes, passing through the endoscope channel into the human body cavity to take the living tissues for pathology analysis.
Model | Jaw open size(mm) | O.D.(mm) | Length(mm) | Serrated Jaw | SPIKE | PE Coating |
ZRH-BFA-2416-PWL | 6 | 2.3 | 1600 | NO | NO | NO |
ZRH-BFA-2418-PWL | 6 | 2.3 | 1800 | NO | NO | NO |
ZRH-BFA-2416-PWS | 6 | 2.3 | 1600 | NO | NO | YES |
ZRH-BFA-2418-PWS | 6 | 2.3 | 1800 | NO | NO | YES |
ZRH-BFA-2416-PZL | 6 | 2.3 | 1600 | NO | YES | NO |
ZRH-BFA-2418-PZL | 6 | 2.3 | 1800 | NO | YES | NO |
ZRH-BFA-2416-PZS | 6 | 2.3 | 1600 | NO | YES | YES |
ZRH-BFA-2418-PZS | 6 | 2.3 | 1800 | NO | YES | YES |
ZRH-BFA-2416-CWL | 6 | 2.3 | 1600 | YES | NO | NO |
ZRH-BFA-2418-CWL | 6 | 2.3 | 1800 | YES | NO | NO |
ZRH-BFA-2416-CWS | 6 | 2.3 | 1600 | YES | NO | YES |
ZRH-BFA-2418-CWS | 6 | 2.3 | 1800 | YES | NO | YES |
ZRH-BFA-2416-CZL | 6 | 2.3 | 1600 | YES | YES | NO |
ZRH-BFA-2418-CZL | 6 | 2.3 | 1800 | YES | YES | NO |
ZRH-BFA-2416-CZS | 6 | 2.3 | 1600 | YES | YES | YES |
ZRH-BFA-2418-CZS | 6 | 2.3 | 1800 | YES | YES | YES |
Intended Use
Biopsy forceps are used for tissue sampling in digestive and respiratory tracts.
PE Coated with Length Markers
Coated with super-lubricious PE for better glide and protection for endoscopic channel.
Length Markers assist with insertion and withdrawal process are available
Excellent Flexibility
Pass through 210 degree curved channel.
How the Disposable Biopsy Forceps Works
The endoscopic biopsy forceps are used to enter the gastrointestinal tract via a flexible endoscope to obtain tissue samples in order to understand disease pathology. The forceps are available in four configurations(oval cup forceps, oval cup forceps with needle, alligator forceps, alligator forceps with needle) to address a variety of clinical needs, including tissue acquisition.
Nowadays, disposable biopsy forceps are widely used. Have you paid attention to these signs? Including the length, the diameter of the biopsy forceps cup, etc. After reading these marks, you can determine the scope of the single use biopsy forceps, whether it is a standard gastroscope, colonoscope, or ultra-fine gastroscope, rhino-gastroscope, etc. The open diameter of the forceps can be used as the basis for judging the size of the lesion under endoscopy.
Many people have used this, but it is not so detailed. Because the estimation of the size of the lesion under the naked eye more or less refers to the open length of the forceps and the diameter of the forceps itself.